<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>aldly</ParameterFamily>
<LongName>
picker_drop_pause
</LongName>
<Name>
pdp
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_400/800_Auto</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_NEWS</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
At the beginning of a load, the picker moves down then vacuum is turned off
to release the plate and let it fall into the clamps.  This parameter specifies the
delay between when vacuum is turned off and when the leading edge clamp closes on
the plate.
</text></DescriptionText>
</Description>
<Type>
uint32
</Type>
<Default>
<UnnumberedList>
<li>0.7 s</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 60 [seconds]</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
Only supported in firmware versions 1.30 and above.
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../commands/load.xml</LinkAddress><LinkTitle>Command: load</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:36:07 2008 PST
</Updated>
<Links>
</Links>
</Parameter>